· 10 or 12 functions selectable by rotary switch, according to model:
- Delay on operate
- Interval on operate
- Delay on operate with time storage, without memory
- Delay on operate by external input, when activate
- Delay on operate by external input, when deactivate
- Delay on operate by external input, when activate or deactivate
- Delay on operate with time storage, with memory
- Interval on operate by external input, when activate
- Interval on operate by external input, when deactivate
- Interval on operate by external input, when activate or deactivate
Multi-range:
· [100]: From 0,01 S up to 100 H selectable by 8-position rotary switch.
· 10 or 12 functions selectable by rotary switch, according to model:
- Delay on operate
- Interval on operate
- Delay on operate with time storage, without memory
- Delay on operate by external input, when activate
- Delay on operate by external input, when deactivate
- Delay on operate by external input, when activate or deactivate
- Delay on operate with time storage, with memory
- Interval on operate by external input, when activate
- Interval on operate by external input, when deactivate
- Interval on operate by external input, when activate or deactivate
-Technical data
PTMA - PTMB - DTMA - DTMB
· Multifunction: Delay on operate, Interval on operate,Clutch.
· Start by external input, sensor NPN or PNP
· Multirange: 0,01 S..100 H
· Supply voltage: VAC, VDC, VAC/DC
+ Documentation
PTMA - DTMA - PTMB - DTMB
· Data sheet
· Data sheet
· Data sheet
· Data sheet
· Declaration of conformity CE
· Declaration of conformity CE
· Declaration of conformity CE
· Declaration of conformity CE
· Safety, installation and maintenance instructions
· Safety, installation and maintenance instructions
· Safety, installation and maintenance instructions
· Safety, installation and maintenance instructions
+Ordering
· Single-voltage models: Determine the supply voltage that the relay will be connected to.
· Single-range models: Choose a time range immediately above than the time to be controlled.
· For all options, see the table "Reference" in the technical documentation of the selected model.
· 10 or 12 functions selectable by rotary switch, according to model:
- Delay on operate
- Interval on operate
- Delay on operate with time storage, without memory
- Delay on operate by external input, when activate
- Delay on operate by external input, when deactivate
- Delay on operate by external input, when activate or deactivate
- Delay on operate with time storage, with memory
- Interval on operate by external input, when activate
- Interval on operate by external input, when deactivate
- Interval on operate by external input, when activate or deactivate
-Technical data
PTMG - DTMG
· Multifunction: Connection, Interval, Clutch,
· Start by external contact, sensor NPN or PNP
· Adjustable by remote potentiometer
· Multirange: 0,01 S..100 H
· Supply voltage: VAC, VDC, VAC/DC
+ Documentation
PTMG - DTMG
· Data sheet
· Data sheet
· Declaration of conformity CE
· Declaration of conformity CE
· Safety, installation and maintenance instructions
· Safety, installation and maintenance instructions
+Ordering
· Single-voltage models: Determine the supply voltage that the relay will be connected to.
· Single-range models: Choose a time range immediately above than the time to be controlled.
· For all options, see the table "Reference" in the technical documentation of the selected model.
· 10 or 12 functions selectable by rotary switch, according to model:
- Delay on operate
- Interval on operate
- Delay on operate with time storage, without memory
- Delay on operate by external input, when activate
- Delay on operate by external input, when deactivate
- Delay on operate by external input, when activate or deactivate
- Delay on operate with time storage, with memory
- Interval on operate by external input, when activate
- Interval on operate by external input, when deactivate
- Interval on operate by external input, when activate or deactivate
-Technical data
PTZA - PTZB - DTZA - DTZB
· Multifunction: Connection, Interval, Clutch
· Manual starter by external contact
· Multirange: 0,01 S..100 H
· Multivoltage: 24..240 VAC/DC
+ Documentation
PTZA - DTZA - PTZB - DTZB
· Data sheet
· Data sheet
· Data sheet
· Data sheet
· Declaration of conformity CE
· Declaration of conformity CE
· Declaration of conformity CE
· Declaration of conformity CE
· Safety, installation and maintenance instructions
· Safety, installation and maintenance instructions
· Safety, installation and maintenance instructions
· Safety, installation and maintenance instructions
+Ordering
· Single-voltage models: Determine the supply voltage that the relay will be connected to.
· Single-range models: Choose a time range immediately above than the time to be controlled.
· For all options, see the table "Reference" in the technical documentation of the selected model.
· 10 or 12 functions selectable by rotary switch, according to model:
- Delay on operate
- Interval on operate
- Delay on operate with time storage, without memory
- Delay on operate by external input, when activate
- Delay on operate by external input, when deactivate
- Delay on operate by external input, when activate or deactivate
- Delay on operate with time storage, with memory
- Interval on operate by external input, when activate
- Interval on operate by external input, when deactivate
- Interval on operate by external input, when activate or deactivate
-Technical data
PTNA - PTNB - DTNA - DTNB
· Multifunction: Connection, Interval, Clutch
· Start by external contact, sensor NPN or PNP
· Instant activation relay
· Multirange: 0.01 S..100 H
· Supply voltage: VAC, VDC, VAC/DC
+ Documentation
PTNA - DTNA - PTNB - DTNB
· Data sheet
· Data sheet
· Data sheet
· Declaration of conformity CE
· Declaration of conformity CE
· Declaration of conformity CE
· Declaration of conformity CE
· Safety, installation and maintenance instructions
· Safety, installation and maintenance instructions
· Safety, installation and maintenance instructions
· Safety, installation and maintenance instructions
+Ordering
· Single-voltage models: Determine the supply voltage that the relay will be connected to.
· Single-range models: Choose a time range immediately above than the time to be controlled.
· For all options, see the table "Reference" in the technical documentation of the selected model.