Tel. 934 560 995
disibeint@disibeint.com
Tel. 934 560 995 - disibeint@disibeint.com
(0)
en

Magnetic switches of variable length

Miniature design, with racord, SS

· For the detection of one or more level points.
· Used in maneuvers for filling, emptying, overfill alarm, etc.
· Because of its small size is ideal for tanks with limited space.
· Custom fabrication to suit the installation conditions.

· Made in SS AISI316 (1.4401)
· Process connection: Nipple 1/8" G
· Electrical connection: Silicone cable
· Float: Cylindrical ø29x32 mm
· Contacts: (NO) 40W/VA-2A/230VAC/DC
· Contacts: (NC and NONC) 20W/VA-1A/150VAC/DC
· Density: 0,71 g/cm³
· Temperature: -40..+125ºC
· Pressure: 15 kg/cm²
· Protection IP65
CONFIGURATOR:
Version
Encapsulated
Internal mode protection
Process connection
Float
Ø29X29
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
Cable (m)

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· Vertical installation
· Length: 50..3500 mm
CONFIGURATOR:
Version
Encapsulated
Internal mode protection
Process connection
1/8"G
Float
Ø29X29
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
Cable (m)

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· For installation in the tank side
· Length: 50..1000 mm