· Exclusive use in conductive liquids, are used to control level points both independent or combined into small tanks or in deep wells.
· Amplifier incorporated into the housing.
· The control function determines the number of electrodes.
· Electrodes made of SS AISI316 (1.4401)
· The electrodes can be cut to adjust the desired level point.
· Output relay SPDT, 6A/250VAC
CONFIGURATOR:
Process connecion
Power supply
Number of electrodes
Length (mm)
1000
All electrodes are delivered at the same length
Electrodes material
SS
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· Exclusive use in conductive liquids, are used to control level points both independent or combined into small tanks or in deep wells.
· Amplifier incorporated into the housing.
· The control function determines the number of electrodes.
-Technical data
· Compact electrodes holder for low height tanks
· The common electrode is the process connection
· Process connection: Nipple 1" G. SS AISI316 (1.4401)
· Electrical connection: Connection housing. PBT
· +70ºC. 5 kg/cm². IP67
· With 1 electrode: control of 1 level point
· With 2 electrodes: control maximum/minimum
+ Documentation
· Data sheet
· Installation and application tips
· Declaration of conformity CE
· Safety, installation and maintenance instructions
+Ordering
· Choose the type of process connection and electrical connection that best fits your installation.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· To know the relationship between the electric resistance and the conductivity of the liquid to be controlled, use the Units converter.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Convertisseur de conductivité
Quantity
Unit
Decimals
Ω
1000000,000
KΩ
1000,000
MΩ
1,000
µSiemens
1,000
mSiemens
0,001
Siemens
0,000
+
CONFIGURATOR:
Process connecion
Power supply
Number of electrodes
Length (mm)
All electrodes are delivered at the same length
Electrodes material
SS
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· Exclusive use in conductive liquids, are used to control level points both independent or combined into small tanks or in deep wells.
· Amplifier incorporated into the housing.
· The control function determines the number of electrodes.
-Technical data
· Compact electrodes holder for low height tanks
· The common electrode is the process connection
· Electrode isolated with PTFE
· Process connection: Nipple 1" G. SS AISI316 (1.4401)
· Electrical connection: Connection housing. PBT
· +70ºC. 5 kg/cm². IP67
· With 1 electrode: control of 1 level point
· With 2 electrodes: control maximum/minimum
+ Documentation
· Data sheet
· Installation and application tips
· Declaration of conformity CE
· Safety, installation and maintenance instructions
+Ordering
· Choose the type of process connection and electrical connection that best fits your installation.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· To know the relationship between the electric resistance and the conductivity of the liquid to be controlled, use the Units converter.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Convertisseur de conductivité
Quantity
Unit
Decimals
Ω
1000000,000
KΩ
1000,000
MΩ
1,000
µSiemens
1,000
mSiemens
0,001
Siemens
0,000
+
CONFIGURATOR:
Process connecion
1"G
Power supply
Number of electrodes
Length (mm)
1000
All electrodes are delivered at the same length
Electrodes material
SS
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· Exclusive use in conductive liquids, are used to control level points both independent or combined into small tanks or in deep wells.
· Amplifier incorporated into the housing.
· The control function determines the number of electrodes.
-Technical data
· Compact electrodes holder for low height tanks
· Process connection: Nipple 1" G. SS AISI316 (1.4401)
· Electrical connection: Connection housing. PBT
· +70ºC. 5 kg/cm². IP67
· With 2 electrodes: control of 1 level point
· With 3 electrodes: control maximum/minimum
+ Documentation
· Data sheet
· Installation and application tips
· Declaration of conformity CE
· Safety, installation and maintenance instructions
+Ordering
· Choose the type of process connection and electrical connection that best fits your installation.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· To know the relationship between the electric resistance and the conductivity of the liquid to be controlled, use the Units converter.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Convertisseur de conductivité
Quantity
Unit
Decimals
Ω
1000000,000
KΩ
1000,000
MΩ
1,000
µSiemens
1,000
mSiemens
0,001
Siemens
0,000
+
CONFIGURATOR:
Process connecion
1"G
Power supply
Number of electrodes
Length (mm)
All electrodes are delivered at the same length
Electrodes material
SS
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· Exclusive use in conductive liquids, are used to control level points both independent or combined into small tanks or in deep wells.
· Amplifier incorporated into the housing.
· The control function determines the number of electrodes.
-Technical data
· Compact electrodes holder for low height tanks
· Electrodes isolated with PTFE
· Process connection: Nipple 1" G. SS AISI316 (1.4401)
· Electrical connection: Connection housing. PBT
· +70ºC. 5 kg/cm². IP67
· With 2 electrodes: control of 1 level point
· With 3 electrodes: control maximum/minimum
+ Documentation
· Data sheet
· Installation and application tips
· Declaration of conformity CE
· Safety, installation and maintenance instructions
+Ordering
· Choose the type of process connection and electrical connection that best fits your installation.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· To know the relationship between the electric resistance and the conductivity of the liquid to be controlled, use the Units converter.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Convertisseur de conductivité
Quantity
Unit
Decimals
Ω
1000000,000
KΩ
1000,000
MΩ
1,000
µSiemens
1,000
mSiemens
0,001
Siemens
0,000
+
CONFIGURATOR:
Process connecion
1"1/2G
Power supply
Number of electrodes
Length (mm)
All electrodes are delivered at the same length
Electrodes material
SS
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· Exclusive use in conductive liquids, are used to control level points both independent or combined into small tanks or in deep wells.
· Amplifier incorporated into the housing.
· The control function determines the number of electrodes.
-Technical data
· Compact electrodes holder for low height tanks
· Process connection: Top screw 1"1/2 G. PVC
· Electrical connection: Connection housing. PBT
· +70 ºC. 5 kg/cm². IP67
· With 2 electrodes: control of 1 level point
· With 3 electrodes: control maximum/minimum
+ Documentation
· Data sheet
· Installation and application tips
· Declaration of conformity CE
· Safety, installation and maintenance instructions
+Ordering
· Choose the type of process connection and electrical connection that best fits your installation.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· To know the relationship between the electric resistance and the conductivity of the liquid to be controlled, use the Units converter.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Convertisseur de conductivité
Quantity
Unit
Decimals
Ω
1000000,000
KΩ
1000,000
MΩ
1,000
µSiemens
1,000
mSiemens
0,001
Siemens
0,000
+
CONFIGURATOR:
Process connecion
1"1/2G
Power supply
Number of electrodes
Length (mm)
All electrodes are delivered at the same length
Electrodes material
SS
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· Exclusive use in conductive liquids, are used to control level points both independent or combined into small tanks or in deep wells.
· Amplifier incorporated into the housing.
· The control function determines the number of electrodes.
-Technical data
· Compact electrodes holder for low height tanks
· Electrodes isolated with Polyolefine PE
· Process connection: Top screw 1"1/2 G. PVC
· Electrical connection: Connection housing. PBT
· +70 ºC. 5 kg/cm². IP67
· With 2 electrodes: control of 1 level point
· With 3 electrodes: control maximum/minimum
+ Documentation
· Data sheet
· Installation and application tips
· Declaration of conformity CE
· Safety, installation and maintenance instructions
+Ordering
· Choose the type of process connection and electrical connection that best fits your installation.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· To know the relationship between the electric resistance and the conductivity of the liquid to be controlled, use the Units converter.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Convertisseur de conductivité
Quantity
Unit
Decimals
Ω
1000000,000
KΩ
1000,000
MΩ
1,000
µSiemens
1,000
mSiemens
0,001
Siemens
0,000
+
CONFIGURATOR:
Process connecion
1"1/2G
Power supply
Number of electrodes
Cable length (m)
Indicate the total sum of the cable length of all the electrodes.
Cable composition
SS/PVC
Wire in stainless steel and PVC coating.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· Exclusive use in conductive liquids, are used to control level points both independent or combined into small tanks or in deep wells.
· Amplifier incorporated into the housing.
· The control function determines the number of electrodes.
-Technical data
· Compact electrodes holder for large height tanks
· Electrode holding: Twisted wire ø3 mm. SS AISI316 (1.4401)
· Process connection: Top screw 1"1/2 G. PVC
· Electrical connection: Connection housing. PBT
· +70 ºC. 5 kg/cm². IP67
· With 2 electrodes: control of 1 level point
· With 3 electrodes: control maximum/minimum
+ Documentation
· Data sheet
· Installation and application tips
· Declaration of conformity CE
· Safety, installation and maintenance instructions
+Ordering
· Choose the type of process connection and electrical connection that best fits your installation.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· To know the relationship between the electric resistance and the conductivity of the liquid to be controlled, use the Units converter.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.