Magnetic switches of variable length

Standard design, with top screw, SS

· For the detection of one or more level points.
· Used in maneuvers for filling, emptying, overfill alarm, etc.
· Custom fabrication to suit the installation conditions.

· Manufactured in SS AISI316 (1.4401)
· Process connection: Top screw. 1"1/2"-2" G
· Float: Spherical ø52 mm
· Contact: (NO) 120W/VA-3A/250VAC/DC
· Contact: (NC - NO/NC) 60W/VA-1A/230VAC/DC
· Density: 0,7 g/cm³
· Temperature: -40..+125 ºC
· Pressure: 30 kg/cm²
CONFIGURATOR:
Version
Internal mode protection
Process connecion
Float
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
Cable (m)

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· Electrical connection: Cable Silicone
· Length: 90..3500 mm
· Protection IP65
CONFIGURATOR:
Version
Internal mode protection
Process connecion
Float
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
Cable (m)

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· For the installation at the tank side
· Electrical connection: Silicone cable
· Length: 90..1000 mm
· Protection IP65
CONFIGURATOR:
Version
Internal mode protection
Process connecion
Float
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· Electrical connection: Connector DIN43650
· Length: 90..3500 mm
· Protection IP65
CONFIGURATOR:
Version
Internal mode protection
Process connecion
Float
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· For the installation at the tank side
· Electrical connection: Connector DIN43650
· Length: 90..1000 mm
· Protection IP65
CONFIGURATOR:
Version
Internal mode protection
Process connecion
Float
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· Electrical connection: Miniature connector M12
· Length: 90..3500 mm
· Protection IP67
CONFIGURATOR:
Version
Internal mode protection
Process connecion
Float
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· For the installation at the tank side
· Electrical connection: Miniature connector M12
· Length: 90..1000 mm
· Protection IP67
CONFIGURATOR:
Version
Internal mode protection
Process connecion
Float
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· Electrical connection: Connection housing. PBT
· Length: 90..3500 mm
· Protection: IP67
CONFIGURATOR:
Version
Internal mode protection
Process connecion
Float
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· For the installation at the tank side
· Electrical connection: Connection housing. PBT
· Length: 90..1000 mm
· Protection: IP67
CONFIGURATOR:
Power supply
Version
Internal mode protection
Process connecion
Float
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
1

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· Includes control maneuver with relay output
· Output: Relay SPDT 6 A / 250 VCA
· Electrical connection: Connection housing. PBT
· Length: 90..3500 mm
· Protection IP67