· For the detection of one or more level points.
· Used in maneuvers for filling, emptying, overflow alarm, etc.
· Manufacturing tailored to meet the conditions of the installation.
· Electrical connection: DIN43650 Connector
· Guide Tube: SS AISI316 (1.4401)
· Length: 90..3500 mm
CONFIGURATOR:
Version
Internal mode protection
Process connection
Ø52 SS
Float
Ø29x50 PA
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· For the detection of one or more level points.
· Used in maneuvers for filling, emptying, overflow alarm, etc.
· Manufacturing tailored to meet the conditions of the installation.
-Technical data
· Process connection: Flange. ø52 mm. SS
· Electrical connection: DIN43650 Connector
· Guide Tube: ø12 mm. SS AISI316 (1.4401)
· Float: Cylindrical ø29x50 mm. PA
· Contact: (NA) 120W/VA-3A/250VCA/CC
· Contact: (NC - NO / NC) 60W/VA-1A/230VCA/CC
· Density: 0,6 g/cm³
· Temperature: -20..+90 ºC
· Pressure: 3 kg/cm²
+ Documentation
· Data sheet
· Declaration of conformity CE
· User manual
· 3D file [.ZIP]
+Ordering
· Determine the total length according to the characteristics of the shell and the liquid level to be controlled.
· Remember to check that the conditions of pressure, temperature and density of your system match those offered by the model chosen.
· According to the maneuver you wish to perform, determine the amount, location and type of contacts. See Table of Connection Diagrams for more information.
· If you have questions regarding the behavior of materials in contact with the liquid you want to control, see Table of chemical resistance.
· To know all the options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Related products
PSPS -DSPS -SSPS
· Weak contacts protection
· To be used in instruments with potential free contacts
PSMS -DSMS
· Contact amplifier with two independent inputs
· To be used in devices with potential free contacts
PSIA -DSIA
· Control for detection of turbulences in liquids
· Delay to the level detection
· Control differential maximum and minimum levels by timing
· To be used in devices with potential free contacts
+
CONFIGURATOR:
Version
Internal mode protection
Process connection
Ø68 PVC
Float
Ø29x50 PA
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· For the detection of one or more level points.
· Used in maneuvers for filling, emptying, overflow alarm, etc.
· Manufacturing tailored to meet the conditions of the installation.
-Technical data
· Process connection: Flange. ø68 mm. PVC
· Electrical connection: DIN43650 Connector
· Guide Tube: ø12 mm. SS AISI316 (1.4401)
· Float: Cylindrical ø29x50 mm. PA
· Contact: (NA) 120W/VA-3A/250VCA/CC
· Contact: (NC - NO/NC) 60W/VA-1A/230VCA/CC
· Density: 0,6 g/cm³
· Temperature: -20..+90 ºC
· Pressure: 3 kg/cm²
+ Documentation
· Data sheet
· Declaration of conformity CE
· User manual
· 3D file [.ZIP]
+Ordering
· Determine the total length according to the characteristics of the shell and the liquid level to be controlled.
· Remember to check that the conditions of pressure, temperature and density of your system match those offered by the model chosen.
· According to the maneuver you wish to perform, determine the amount, location and type of contacts. See Table of Connection Diagrams for more information.
· If you have questions regarding the behavior of materials in contact with the liquid you want to control, see Table of chemical resistance.
· To know all the options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Related products
PSPS -DSPS -SSPS
· Weak contacts protection
· To be used in instruments with potential free contacts
PSMS -DSMS
· Contact amplifier with two independent inputs
· To be used in devices with potential free contacts
PSIA -DSIA
· Control for detection of turbulences in liquids
· Delay to the level detection
· Control differential maximum and minimum levels by timing
· To be used in devices with potential free contacts
+
CONFIGURATOR:
Version
Internal mode protection
Process connecion
1"G
Float
Ø29x50 PA
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· For the detection of one or more level points.
· Used in maneuvers for filling, emptying, overflow alarm, etc.
· Manufacturing tailored to meet the conditions of the installation.
-Technical data
· Process connection: Top screw. 1" G. PVC
· Electrical connection: DIN43650 Connector
· Guide Tube: ø12 mm. SS AISI316 (1.4401)
· Float: Cylindrical ø29x50 mm. PA
· Contact: (NA) 120W/VA-3A/250VCA/CC
· Contact: (NC - NO / NC) 60W/VA-1A/230VCA/CC
· Density: 0,6 g/cm³
· Temperature: -20..+90 ºC
· Pressure: 3 kg/cm²
+ Documentation
· Data sheet
· Declaration of conformity CE
· User manual
· Configure IMN
+Ordering
· Determine the total length according to the characteristics of the shell and the liquid level to be controlled.
· Remember to check that the conditions of pressure, temperature and density of your system match those offered by the model chosen.
· According to the maneuver you wish to perform, determine the amount, location and type of contacts. See Table of Connection Diagrams for more information.
· If you have questions regarding the behavior of materials in contact with the liquid you want to control, see Table of chemical resistance.
· To know all the options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Related products
PSPS -DSPS -SSPS
· Weak contacts protection
· To be used in instruments with potential free contacts
PSMS -DSMS
· Contact amplifier with two independent inputs
· To be used in devices with potential free contacts
PSIA -DSIA
· Control for detection of turbulences in liquids
· Delay to the level detection
· Control differential maximum and minimum levels by timing
· To be used in devices with potential free contacts
+
CONFIGURATOR:
Version
Internal mode protection
Process connecion
Float
Ø29x50 PA
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· For the detection of one or more level points.
· Used in maneuvers for filling, emptying, overflow alarm, etc.
· Manufacturing tailored to meet the conditions of the installation.
-Technical data
· Process connection: Top screw. 1"G .. 2"G. PVC
· Electrical connection: Housing, PBT
· Guide Tube: ø12 mm. SS AISI316 (1.4401)
· Float: Cylindrical ø29x50 mm. PA
· Contact: (NA) 120W/VA-3A/250VCA/CC
· Contact: (NC - NO/NC) 60W/VA-1A/230VCA/CC
· Density: 0,6 g/cm³
· Temperature: -20..+90 ºC
· Pressure: 3 kg/cm²
+ Documentation
· Data sheet
· Module for RS485 output
· User manual
· Declaration of conformity CE
· Configure IMN
+Ordering
· Determine the total length according to the characteristics of the shell and the liquid level to be controlled.
· Remember to check that the conditions of pressure, temperature and density of your system match those offered by the model chosen.
· According to the maneuver you wish to perform, determine the amount, location and type of contacts. See Table of Connection Diagrams for more information.
· If you have questions regarding the behavior of materials in contact with the liquid you want to control, see Table of chemical resistance.
· To know all the options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Related products
PSPS -DSPS -SSPS
· Weak contacts protection
· To be used in instruments with potential free contacts
PSMS -DSMS
· Contact amplifier with two independent inputs
· To be used in devices with potential free contacts
PSIA -DSIA
· Control for detection of turbulences in liquids
· Delay to the level detection
· Control differential maximum and minimum levels by timing
· To be used in devices with potential free contacts
+
CONFIGURATOR:
Version
Internal mode protection
Process connecion
3/4"G
Float
Ø25x25
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· For the detection of one or more level points.
· Used in maneuvers for filling, emptying, overflow alarm, etc.
· Manufacturing tailored to meet the conditions of the installation.
-Technical data
· Process connection: Top screw. 3/4" G. PVC
· Electrical connection: Connector DIN43650 Mini
· Guide Tube: ø8 mm. SS AISI316 (1.4401)
· Float: Cylindrical ø25x25 mm. PP
· Contact: (NA) 40W/VA-2A/230VCA/CC
· Contact: (NC - NO/NC) 20W/VA-1A/150VCA/CC
· Density: 0,5 g/cm³
· Temperature: -30..+85 ºC
· Pressure: 2 kg/cm²
+ Documentation
· 3D file [.ZIP]
+Ordering
· Determine the total length according to the characteristics of the shell and the liquid level to be controlled.
· Remember to check that the conditions of pressure, temperature and density of your system match those offered by the model chosen.
· According to the maneuver you wish to perform, determine the amount, location and type of contacts. See Table of Connection Diagrams for more information.
· If you have questions regarding the behavior of materials in contact with the liquid you want to control, see Table of chemical resistance.
· To know all the options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Related products
PSPS -DSPS -SSPS
· Weak contacts protection
· To be used in instruments with potential free contacts
PSMS -DSMS
· Contact amplifier with two independent inputs
· To be used in devices with potential free contacts
PSIA -DSIA
· Control for detection of turbulences in liquids
· Delay to the level detection
· Control differential maximum and minimum levels by timing
· To be used in devices with potential free contacts
+
CONFIGURATOR:
Version
Internal mode protection
Process connecion
3/4"G
Float
Ø25x25
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· For the detection of one or more level points.
· Used in maneuvers for filling, emptying, overflow alarm, etc.
· Manufacturing tailored to meet the conditions of the installation.
-Technical data
· Process connection: Top screw. 3/4"G SS
· Electrical connection: DIN43650 Connector Mini
· Guide Tube: ø8 mm. SS AISI316 (1.4401)
· Float: Cylindrical ø25x25 mm. PP
· Contact: (NA) 40W/VA-2A/230VCA/CC
· Contact: (NC - NO / NC) 40W/VA-2A/230VCA/CC
· Density: 0,5 g/cm³
· Temperature: -30..+85 ºC
· Pressure: 2 kg/cm²
+ Documentation
· Data sheet
· Declaration of conformity CE
· User manual
· Configure IMN
· 3D file [.ZIP]
+Ordering
· Determine the total length according to the characteristics of the shell and the liquid level to be controlled.
· Remember to check that the conditions of pressure, temperature and density of your system match those offered by the model chosen.
· According to the maneuver you wish to perform, determine the amount, location and type of contacts. See Table of Connection Diagrams for more information.
· If you have questions regarding the behavior of materials in contact with the liquid you want to control, see Table of chemical resistance.
· To know all the options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Related products
PSPS -DSPS -SSPS
· Weak contacts protection
· To be used in instruments with potential free contacts
PSMS -DSMS
· Contact amplifier with two independent inputs
· To be used in devices with potential free contacts
PSIA -DSIA
· Control for detection of turbulences in liquids
· Delay to the level detection
· Control differential maximum and minimum levels by timing
· To be used in devices with potential free contacts
+
CONFIGURATOR:
Version
Internal mode protection
Process connecion
Float
Ø29x50 PA
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· For the detection of one or more level points.
· Used in maneuvers for filling, emptying, overflow alarm, etc.
· Manufacturing tailored to meet the conditions of the installation.
-Technical data
· Process connection: Top screw. 1´´G .. 2´´G. PP
· Electrical connection: Housing, PBT
· Guide Tube: ø12 mm. PP
· Float: Cylindrical ø29x50 mm. PA
· Contact: (NA) 120W/VA-3A/250VCA/CC
· Contact: (NC - NO/NC) 60W/VA-1A/230VCA/CC
· Density: 0,6 g/cm³
· Temperature: -20..+90 ºC
· Pressure: 3 kg/cm²
+ Documentation
· Data sheet
· Module for RS485 output
· User manual
· Declaration of conformity CE
· Configure IMN
+Ordering
· Determine the total length according to the characteristics of the shell and the liquid level to be controlled.
· Remember to check that the conditions of pressure, temperature and density of your system match those offered by the model chosen.
· According to the maneuver you wish to perform, determine the amount, location and type of contacts. See Table of Connection Diagrams for more information.
· If you have questions regarding the behavior of materials in contact with the liquid you want to control, see Table of chemical resistance.
· To know all the options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Related products
PSPS -DSPS -SSPS
· Weak contacts protection
· To be used in instruments with potential free contacts
PSMS -DSMS
· Contact amplifier with two independent inputs
· To be used in devices with potential free contacts
PSIA -DSIA
· Control for detection of turbulences in liquids
· Delay to the level detection
· Control differential maximum and minimum levels by timing
· To be used in devices with potential free contacts
+
CONFIGURATOR:
Version
Internal mode protection
Process connecion
Float
Ø29x50 PA
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· For the detection of one or more level points.
· Used in maneuvers for filling, emptying, overflow alarm, etc.
· Manufacturing tailored to meet the conditions of the installation.
-Technical data
· Process connection: Top screw. 1´´..2´´ G. PP
· Electrical connection: DIN43650 Connector
· Guide Tube: ø12 mm. PP
· Float: Cylindrical ø29x50 mm. PA
· Contact: (NA) 120W/VA-3A/250VCA/CC
· Contact: (NC - NO / NC) 60W/VA-1A/230VCA/CC
· Density: 0,6 g/cm³
· Temperature: -20..+90 ºC
· Pressure: 3 kg/cm²
+ Documentation
· Data sheet
· User manual
· Declaration of conformity CE
· Configure IMN
· 3D file [.ZIP]
+Ordering
· Determine the total length according to the characteristics of the shell and the liquid level to be controlled.
· Remember to check that the conditions of pressure, temperature and density of your system match those offered by the model chosen.
· According to the maneuver you wish to perform, determine the amount, location and type of contacts. See Table of Connection Diagrams for more information.
· If you have questions regarding the behavior of materials in contact with the liquid you want to control, see Table of chemical resistance.
· To know all the options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Related products
PSPS -DSPS -SSPS
· Weak contacts protection
· To be used in instruments with potential free contacts
PSMS -DSMS
· Contact amplifier with two independent inputs
· To be used in devices with potential free contacts
PSIA -DSIA
· Control for detection of turbulences in liquids
· Delay to the level detection
· Control differential maximum and minimum levels by timing
· To be used in devices with potential free contacts