Magnetic switches of variable length

Miniature design, with top screw, SS

· For the detection of one or more level points.
· Used in maneuvers for filling, emptying, overfill alarm, etc.
· Because of its small size is ideal for tanks with limited space.
· Custom fabrication to suit the installation conditions.

· Made in SS AISI316 (1.4401)
· Process connection: Top screw. 1"-1"1/4 G
· Float: Cylindrical ø29x32 mm
· Contacts: (NO) 40W/VA-2A/230VAC/DC
· Contacts: (NC and NONC) 20W/VA-1A/150VAC/DC
· Density: 0,71 g/cm³
· Temperature: -40..+125ºC
· Pressure: 20 kg/cm²
CONFIGURATOR:
Version
Internal mode protection
Process connection
Float
Ø29X29
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
Cable (m)

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· Electrical connection: Silicone cable
· Length: 50..3500 mm
· Protection: IP65
CONFIGURATOR:
Version
Internal mode protection
Process connection
Float
Ø29X29
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
Cable (m)

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· For installation on the side of the tank
· Electrical connection: Silicone cable
· Length: 50..1000 mm
· Bent elbow: 90º
· Protection: IP65
CONFIGURATOR:
Version
Internal mode protection
Process connection
Float
Ø29X29
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· Electrical connection: Connector DIN43650
· Length: 100..3500 mm
· Protection: IP65
CONFIGURATOR:
Version
Internal mode protection
Process connection
Float
Ø29X29
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· For instalation in the tank side
· Electrical connection: Connector DIN43650
· Length: 50..1000 mm
· Bent in elbow 90º
· Protection: IP65
CONFIGURATOR:
Version
Internal mode protection
Process connection
Float
Ø29X29
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· Electrical connection: Miniature connector M12. The female connector is not supplied
· Length: 100..3500 mm
· Protection: IP67
CONFIGURATOR:
Version
Internal mode protection
Process connection
Float
Ø29X29
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· For installation on the side of the tank
· Connecting power: Miniature connector M12. The female connector is not supplied
· Length: 100..1000 mm
· Bent in elbow 90º
· Protection: IP67
CONFIGURATOR:
Version
Internal mode protection
Process connection
Float
Ø29X29
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· Process connection: Top screw. 1"-1"1/4 G
· Electrical connection: Connection housing. PBT
· Length: 100..3500 mm
· Protection: IP67
CONFIGURATOR:
Version
Internal mode protection
Process connection
Float
Ø29X29
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· For installation on the side of the tank
· Electrical connection: Connection housing. PBT
· Length: 50..1000 mm
· Bent elbow 90º
· Protection: IP67
CONFIGURATOR:
Power supply
Version
Internal mode protection
Process connection
Float
Ø29X29
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
1

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· Includes control maneuver with relay output
· Output: Relay SPDT 6 A / 250 VCA
· Electrical connection: Connection housing. PBT
· Length: 100..3500 mm
· Protection: IP67