· The by-pass indicators are used to visually and/or electrically control the volume of liquid in the tank.
· They are installed outside the tank as a communicating vessel.
· They can incorporate electrical elements of measurement and control for the automation of the process.
· Custom fabrication to suit the installation conditions.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· The by-pass indicators are used to visually and/or electrically control the volume of liquid in the tank.
· They are installed outside the tank as a communicating vessel.
· They can incorporate electrical elements of measurement and control for the automation of the process.
· Custom fabrication to suit the installation conditions.
-Technical data
· Electric water level control in tanks and visual
· Side mounting
· Several options for the process connection
· Manufactured in SS AISI316 (1.4401)
+ Documentation
· Data sheet
· Declaration of conformity CE
+Ordering
· Determine the total length according to the characteristics of the tank and the liquid level you want to control.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Related products
IMN OP-EL INOX
· Level switch manufactured in SS AISI316 (1.4401)
· Process connection : Female thread 3/4" G. Aluminium
· Electrical connection: Silicone cable
· Glass: ø66 mm. Pyrex
· Length: 100..2000 mm
· Temperature: -30..+130 ºC
. Protection: IP 65
IMN OP-EL PVC
· Viewfinder and level switch set
· Lower and upper ends: PP
· Glass: ø50 mm, Pyrex
· Glass protector: PVC
· Connection level switch: 1 ´´G
· Connection process: Thread 3/4 ´´G, lateral or inferior
· Length: 100..2000 mm
· Temperature: -30 .. + 65 ºC
· Protection: IP65
FCPP06M18
· Float for BPCBA-50 contact
· Manufactured in PP
· Temperature: -10..+80 ºC
· Dimensions: Ø38x60 mm
· Density: 0,7 g/cm3
IBT 32 PVC
· Control optical and/or electrical of the level in tanks at atmospheric pressure
· Compound elbows, counterweight and signaling (for the other pieces, see accessories)
· Process connection: Flange DN25, PVC
· Tube: ø32 mm. PVC Glass
· Temperature: -10..+60 ºC
IBT 63 PVC
· Control optical and/or electrical of the level in tanks at atmospheric pressure
· Compound elbows, counterweight and float (for the other pieces, see accessories)
· Process connection: Flange ø110 mm, PVC
· Tube: ø63 mm. PVC Glass
· Temperature: -10..+60 ºC
TMN 300 BP INOX
· Magnetic transducer for continuous level reading
· Output: Analog 4..20 mA, 10..35VDC
· Process connection: Clamp flange SS AISI304 (1.4301)
· Measurement distance up to 2500 mm
· Electrical connection: Connection housing. PBT
· Temperature: -20..+100ºC
BPCB-63
· Detection of the level in pipes or in by-pass sensors
· Assembly on the outside of a tube ø63 mm
· Output: Bistable reed 2A/230VCA
· Contact NO or NC according to the position of all
· Electrical connection: DIN43650 connector
CBBP-63
· Float for BPCB-63 contact
· Manufactured in PP
· Temperature: -10..+80 ºC
· Dimensions: Ø49x130 mm
· Density: 0,7 g/cm3
BPCBA-50
· Detection of the level in pipes or in by-pass sensors
· Assembly on the outside of a tube ø 50 mm
· Output: Bistable reed 2A/230VAC
· Contact NO or NC according to the position of all
· Electrical connection: DIN43650 connector
IMN OP-EL PP
· Viewfinder and level switch set
· Process connection : Female thread 3/4´´ G. Aluminium
· Electrical connection: Silicone cable
· Glass: ø66 mm. Pyrex
· Length: 100..2000 mm
· Temperature: -30 .. + 65 ºC
· Protection: IP65
CPCI-32
· Float for BPCBA-50 contact
· Manufactured in PA
· Temperature: -10..+80 ºC
· Dimensions: Ø25x97 mm
· Density: 0,7 g/cm3
+
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· The by-pass indicators are used to visually and/or electrically control the volume of liquid in the tank.
· They are installed outside the tank as a communicating vessel.
· They can incorporate electrical elements of measurement and control for the automation of the process.
· Custom fabrication to suit the installation conditions.
-Technical data
· Electrical and visual level control in tanks
· Side mounting
· Different posibilities to process connection
· Manufactured in Polypropylene
+ Documentation
· Data sheet
· Declaration of conformity CE
+Ordering
· Determine the total length according to the characteristics of the tank and the liquid level you want to control.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Related products
IMN OP-EL INOX
· Level switch manufactured in SS AISI316 (1.4401)
· Process connection : Female thread 3/4" G. Aluminium
· Electrical connection: Silicone cable
· Glass: ø66 mm. Pyrex
· Length: 100..2000 mm
· Temperature: -30..+130 ºC
. Protection: IP 65
IMN OP-EL PVC
· Viewfinder and level switch set
· Lower and upper ends: PP
· Glass: ø50 mm, Pyrex
· Glass protector: PVC
· Connection level switch: 1 ´´G
· Connection process: Thread 3/4 ´´G, lateral or inferior
· Length: 100..2000 mm
· Temperature: -30 .. + 65 ºC
· Protection: IP65
FCPP06M18
· Float for BPCBA-50 contact
· Manufactured in PP
· Temperature: -10..+80 ºC
· Dimensions: Ø38x60 mm
· Density: 0,7 g/cm3
IBT 32 PVC
· Control optical and/or electrical of the level in tanks at atmospheric pressure
· Compound elbows, counterweight and signaling (for the other pieces, see accessories)
· Process connection: Flange DN25, PVC
· Tube: ø32 mm. PVC Glass
· Temperature: -10..+60 ºC
IBT 63 PVC
· Control optical and/or electrical of the level in tanks at atmospheric pressure
· Compound elbows, counterweight and float (for the other pieces, see accessories)
· Process connection: Flange ø110 mm, PVC
· Tube: ø63 mm. PVC Glass
· Temperature: -10..+60 ºC
TMN 300 BP INOX
· Magnetic transducer for continuous level reading
· Output: Analog 4..20 mA, 10..35VDC
· Process connection: Clamp flange SS AISI304 (1.4301)
· Measurement distance up to 2500 mm
· Electrical connection: Connection housing. PBT
· Temperature: -20..+100ºC
BPCB-63
· Detection of the level in pipes or in by-pass sensors
· Assembly on the outside of a tube ø63 mm
· Output: Bistable reed 2A/230VCA
· Contact NO or NC according to the position of all
· Electrical connection: DIN43650 connector
CBBP-63
· Float for BPCB-63 contact
· Manufactured in PP
· Temperature: -10..+80 ºC
· Dimensions: Ø49x130 mm
· Density: 0,7 g/cm3
BPCBA-50
· Detection of the level in pipes or in by-pass sensors
· Assembly on the outside of a tube ø 50 mm
· Output: Bistable reed 2A/230VAC
· Contact NO or NC according to the position of all
· Electrical connection: DIN43650 connector
IMN OP-EL PP
· Viewfinder and level switch set
· Process connection : Female thread 3/4´´ G. Aluminium
· Electrical connection: Silicone cable
· Glass: ø66 mm. Pyrex
· Length: 100..2000 mm
· Temperature: -30 .. + 65 ºC
· Protection: IP65
CPCI-32
· Float for BPCBA-50 contact
· Manufactured in PA
· Temperature: -10..+80 ºC
· Dimensions: Ø25x97 mm
· Density: 0,7 g/cm3
+
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· The by-pass indicators are used to visually and/or electrically control the volume of liquid in the tank.
· They are installed outside the tank as a communicating vessel.
· They can incorporate electrical elements of measurement and control for the automation of the process.
· Custom fabrication to suit the installation conditions.
-Technical data
· Electric water level control in tanks and visual
· Side mounting
· Options for connection to process
· Manufactured in PVDF
+ Documentation
· Data sheet
· Declaration of conformity CE
+Ordering
· Determine the total length according to the characteristics of the tank and the liquid level you want to control.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Related products
IMN OP-EL INOX
· Level switch manufactured in SS AISI316 (1.4401)
· Process connection : Female thread 3/4" G. Aluminium
· Electrical connection: Silicone cable
· Glass: ø66 mm. Pyrex
· Length: 100..2000 mm
· Temperature: -30..+130 ºC
. Protection: IP 65
IMN OP-EL PVC
· Viewfinder and level switch set
· Lower and upper ends: PP
· Glass: ø50 mm, Pyrex
· Glass protector: PVC
· Connection level switch: 1 ´´G
· Connection process: Thread 3/4 ´´G, lateral or inferior
· Length: 100..2000 mm
· Temperature: -30 .. + 65 ºC
· Protection: IP65
FCPP06M18
· Float for BPCBA-50 contact
· Manufactured in PP
· Temperature: -10..+80 ºC
· Dimensions: Ø38x60 mm
· Density: 0,7 g/cm3
IBT 32 PVC
· Control optical and/or electrical of the level in tanks at atmospheric pressure
· Compound elbows, counterweight and signaling (for the other pieces, see accessories)
· Process connection: Flange DN25, PVC
· Tube: ø32 mm. PVC Glass
· Temperature: -10..+60 ºC
IBT 63 PVC
· Control optical and/or electrical of the level in tanks at atmospheric pressure
· Compound elbows, counterweight and float (for the other pieces, see accessories)
· Process connection: Flange ø110 mm, PVC
· Tube: ø63 mm. PVC Glass
· Temperature: -10..+60 ºC
TMN 300 BP INOX
· Magnetic transducer for continuous level reading
· Output: Analog 4..20 mA, 10..35VDC
· Process connection: Clamp flange SS AISI304 (1.4301)
· Measurement distance up to 2500 mm
· Electrical connection: Connection housing. PBT
· Temperature: -20..+100ºC
BPCB-63
· Detection of the level in pipes or in by-pass sensors
· Assembly on the outside of a tube ø63 mm
· Output: Bistable reed 2A/230VCA
· Contact NO or NC according to the position of all
· Electrical connection: DIN43650 connector
CBBP-63
· Float for BPCB-63 contact
· Manufactured in PP
· Temperature: -10..+80 ºC
· Dimensions: Ø49x130 mm
· Density: 0,7 g/cm3
BPCBA-50
· Detection of the level in pipes or in by-pass sensors
· Assembly on the outside of a tube ø 50 mm
· Output: Bistable reed 2A/230VAC
· Contact NO or NC according to the position of all
· Electrical connection: DIN43650 connector
IMN OP-EL PP
· Viewfinder and level switch set
· Process connection : Female thread 3/4´´ G. Aluminium
· Electrical connection: Silicone cable
· Glass: ø66 mm. Pyrex
· Length: 100..2000 mm
· Temperature: -30 .. + 65 ºC
· Protection: IP65
CPCI-32
· Float for BPCBA-50 contact
· Manufactured in PA
· Temperature: -10..+80 ºC
· Dimensions: Ø25x97 mm
· Density: 0,7 g/cm3
+
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· The by-pass indicators are used to visually and/or electrically control the volume of liquid in the tank.
· They are installed outside the tank as a communicating vessel.
· They can incorporate electrical elements of measurement and control for the automation of the process.
· Custom fabrication to suit the installation conditions.
-Technical data
· Electric and visual level control in tanks
· Top mounting
· Options for connection to process
· Manufactured in SS AISI316 (1.4401)
+ Documentation
· Declaration of conformity CE
+Ordering
· Determine the total length according to the characteristics of the tank and the liquid level you want to control.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Related products
IMN OP-EL INOX
· Level switch manufactured in SS AISI316 (1.4401)
· Process connection : Female thread 3/4" G. Aluminium
· Electrical connection: Silicone cable
· Glass: ø66 mm. Pyrex
· Length: 100..2000 mm
· Temperature: -30..+130 ºC
. Protection: IP 65
IMN OP-EL PVC
· Viewfinder and level switch set
· Lower and upper ends: PP
· Glass: ø50 mm, Pyrex
· Glass protector: PVC
· Connection level switch: 1 ´´G
· Connection process: Thread 3/4 ´´G, lateral or inferior
· Length: 100..2000 mm
· Temperature: -30 .. + 65 ºC
· Protection: IP65
FCPP06M18
· Float for BPCBA-50 contact
· Manufactured in PP
· Temperature: -10..+80 ºC
· Dimensions: Ø38x60 mm
· Density: 0,7 g/cm3
IBT 32 PVC
· Control optical and/or electrical of the level in tanks at atmospheric pressure
· Compound elbows, counterweight and signaling (for the other pieces, see accessories)
· Process connection: Flange DN25, PVC
· Tube: ø32 mm. PVC Glass
· Temperature: -10..+60 ºC
IBT 63 PVC
· Control optical and/or electrical of the level in tanks at atmospheric pressure
· Compound elbows, counterweight and float (for the other pieces, see accessories)
· Process connection: Flange ø110 mm, PVC
· Tube: ø63 mm. PVC Glass
· Temperature: -10..+60 ºC
TMN 300 BP INOX
· Magnetic transducer for continuous level reading
· Output: Analog 4..20 mA, 10..35VDC
· Process connection: Clamp flange SS AISI304 (1.4301)
· Measurement distance up to 2500 mm
· Electrical connection: Connection housing. PBT
· Temperature: -20..+100ºC
BPCB-63
· Detection of the level in pipes or in by-pass sensors
· Assembly on the outside of a tube ø63 mm
· Output: Bistable reed 2A/230VCA
· Contact NO or NC according to the position of all
· Electrical connection: DIN43650 connector
CBBP-63
· Float for BPCB-63 contact
· Manufactured in PP
· Temperature: -10..+80 ºC
· Dimensions: Ø49x130 mm
· Density: 0,7 g/cm3
BPCBA-50
· Detection of the level in pipes or in by-pass sensors
· Assembly on the outside of a tube ø 50 mm
· Output: Bistable reed 2A/230VAC
· Contact NO or NC according to the position of all
· Electrical connection: DIN43650 connector
IMN OP-EL PP
· Viewfinder and level switch set
· Process connection : Female thread 3/4´´ G. Aluminium
· Electrical connection: Silicone cable
· Glass: ø66 mm. Pyrex
· Length: 100..2000 mm
· Temperature: -30 .. + 65 ºC
· Protection: IP65
CPCI-32
· Float for BPCBA-50 contact
· Manufactured in PA
· Temperature: -10..+80 ºC
· Dimensions: Ø25x97 mm
· Density: 0,7 g/cm3
+
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· The by-pass indicators are used to visually and/or electrically control the volume of liquid in the tank.
· They are installed outside the tank as a communicating vessel.
· They can incorporate electrical elements of measurement and control for the automation of the process.
· Custom fabrication to suit the installation conditions.
-Technical data
· By-pass adapter to switch or magnetic transducer
· Manufactured in SS AISI316 (1.4401)
+ Documentation
· Declaration of conformity CE
+Ordering
· Determine the total length according to the characteristics of the tank and the liquid level you want to control.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Related products
IMN OP-EL INOX
· Level switch manufactured in SS AISI316 (1.4401)
· Process connection : Female thread 3/4" G. Aluminium
· Electrical connection: Silicone cable
· Glass: ø66 mm. Pyrex
· Length: 100..2000 mm
· Temperature: -30..+130 ºC
. Protection: IP 65
IMN OP-EL PVC
· Viewfinder and level switch set
· Lower and upper ends: PP
· Glass: ø50 mm, Pyrex
· Glass protector: PVC
· Connection level switch: 1 ´´G
· Connection process: Thread 3/4 ´´G, lateral or inferior
· Length: 100..2000 mm
· Temperature: -30 .. + 65 ºC
· Protection: IP65
FCPP06M18
· Float for BPCBA-50 contact
· Manufactured in PP
· Temperature: -10..+80 ºC
· Dimensions: Ø38x60 mm
· Density: 0,7 g/cm3
IBT 32 PVC
· Control optical and/or electrical of the level in tanks at atmospheric pressure
· Compound elbows, counterweight and signaling (for the other pieces, see accessories)
· Process connection: Flange DN25, PVC
· Tube: ø32 mm. PVC Glass
· Temperature: -10..+60 ºC
IBT 63 PVC
· Control optical and/or electrical of the level in tanks at atmospheric pressure
· Compound elbows, counterweight and float (for the other pieces, see accessories)
· Process connection: Flange ø110 mm, PVC
· Tube: ø63 mm. PVC Glass
· Temperature: -10..+60 ºC
TMN 300 BP INOX
· Magnetic transducer for continuous level reading
· Output: Analog 4..20 mA, 10..35VDC
· Process connection: Clamp flange SS AISI304 (1.4301)
· Measurement distance up to 2500 mm
· Electrical connection: Connection housing. PBT
· Temperature: -20..+100ºC
BPCB-63
· Detection of the level in pipes or in by-pass sensors
· Assembly on the outside of a tube ø63 mm
· Output: Bistable reed 2A/230VCA
· Contact NO or NC according to the position of all
· Electrical connection: DIN43650 connector
CBBP-63
· Float for BPCB-63 contact
· Manufactured in PP
· Temperature: -10..+80 ºC
· Dimensions: Ø49x130 mm
· Density: 0,7 g/cm3
BPCBA-50
· Detection of the level in pipes or in by-pass sensors
· Assembly on the outside of a tube ø 50 mm
· Output: Bistable reed 2A/230VAC
· Contact NO or NC according to the position of all
· Electrical connection: DIN43650 connector
IMN OP-EL PP
· Viewfinder and level switch set
· Process connection : Female thread 3/4´´ G. Aluminium
· Electrical connection: Silicone cable
· Glass: ø66 mm. Pyrex
· Length: 100..2000 mm
· Temperature: -30 .. + 65 ºC
· Protection: IP65
CPCI-32
· Float for BPCBA-50 contact
· Manufactured in PA
· Temperature: -10..+80 ºC
· Dimensions: Ø25x97 mm
· Density: 0,7 g/cm3
+
CONFIGURATOR:
Process connection
Electrical control
Choose what type of electrical control you want to incorporate to the outside of the bypass display.
Material
PVC
Tube diameter
Float
The float must be smaller in diameter than the process connection.
Top finish
Define how the top of the tube ends.
Bottom finish
Define how the bottom of the tube ends.
Distance between centers
Express the distance (in mm) between the centers of the process connection.
Lower distance
Express the distance (in mm) between the center of the lower process connection and the end of the tube.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· The by-pass indicators are used to visually and/or electrically control the volume of liquid in the tank.
· They are installed outside the tank as a communicating vessel.
· They can incorporate electrical elements of measurement and control for the automation of the process.
· Custom fabrication to suit the installation conditions.
-Technical data
· By-pass level indicator with double process connection
· Manufactured in transparent PVC
+ Documentation
· Data sheet
· Declaration of conformity CE
+Ordering
· Determine the total length according to the characteristics of the tank and the liquid level you want to control.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+Related products
IMN OP-EL INOX
· Level switch manufactured in SS AISI316 (1.4401)
· Process connection : Female thread 3/4" G. Aluminium
· Electrical connection: Silicone cable
· Glass: ø66 mm. Pyrex
· Length: 100..2000 mm
· Temperature: -30..+130 ºC
. Protection: IP 65
IMN OP-EL PVC
· Viewfinder and level switch set
· Lower and upper ends: PP
· Glass: ø50 mm, Pyrex
· Glass protector: PVC
· Connection level switch: 1 ´´G
· Connection process: Thread 3/4 ´´G, lateral or inferior
· Length: 100..2000 mm
· Temperature: -30 .. + 65 ºC
· Protection: IP65
FCPP06M18
· Float for BPCBA-50 contact
· Manufactured in PP
· Temperature: -10..+80 ºC
· Dimensions: Ø38x60 mm
· Density: 0,7 g/cm3
IBT 32 PVC
· Control optical and/or electrical of the level in tanks at atmospheric pressure
· Compound elbows, counterweight and signaling (for the other pieces, see accessories)
· Process connection: Flange DN25, PVC
· Tube: ø32 mm. PVC Glass
· Temperature: -10..+60 ºC
IBT 63 PVC
· Control optical and/or electrical of the level in tanks at atmospheric pressure
· Compound elbows, counterweight and float (for the other pieces, see accessories)
· Process connection: Flange ø110 mm, PVC
· Tube: ø63 mm. PVC Glass
· Temperature: -10..+60 ºC
TMN 300 BP INOX
· Magnetic transducer for continuous level reading
· Output: Analog 4..20 mA, 10..35VDC
· Process connection: Clamp flange SS AISI304 (1.4301)
· Measurement distance up to 2500 mm
· Electrical connection: Connection housing. PBT
· Temperature: -20..+100ºC
BPCB-63
· Detection of the level in pipes or in by-pass sensors
· Assembly on the outside of a tube ø63 mm
· Output: Bistable reed 2A/230VCA
· Contact NO or NC according to the position of all
· Electrical connection: DIN43650 connector
CBBP-63
· Float for BPCB-63 contact
· Manufactured in PP
· Temperature: -10..+80 ºC
· Dimensions: Ø49x130 mm
· Density: 0,7 g/cm3
BPCBA-50
· Detection of the level in pipes or in by-pass sensors
· Assembly on the outside of a tube ø 50 mm
· Output: Bistable reed 2A/230VAC
· Contact NO or NC according to the position of all
· Electrical connection: DIN43650 connector
IMN OP-EL PP
· Viewfinder and level switch set
· Process connection : Female thread 3/4´´ G. Aluminium
· Electrical connection: Silicone cable
· Glass: ø66 mm. Pyrex
· Length: 100..2000 mm
· Temperature: -30 .. + 65 ºC
· Protection: IP65
CPCI-32
· Float for BPCBA-50 contact
· Manufactured in PA
· Temperature: -10..+80 ºC
· Dimensions: Ø25x97 mm
· Density: 0,7 g/cm3