The variation of the electrical resistance depending on the position of the float is what determines the level of liquid in the tank.
The reading resolution is 5 or 10 mm and the measurement distance can be requested so that it is established at the precise distance you want to measure.
· They are used to obtain a continuous reading of liquid level.
· When the float rises or falls due to the action of the liquid, are activated or deactivated respectively a series of reed switches that generate an output proportional to the height of the level.
· Output type: Resistive. 100 ohms/reading
· Distance between contacts: 10 mm. Optional 5 mm.
· Protection: IP67
CONFIGURATOR:
Process connection
Float
The float must be smaller in diameter than the process connection.
Step between readings
Length (mm)
The final length is calculated based on different parameters and may be different from that requested.
Zone E (mm)
Separation between the process connection and the electrical connection.
Zone S (mm)
Distance without reading between the process connection and the highest position of the float.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· They are used to obtain a continuous reading of liquid level.
· When the float rises or falls due to the action of the liquid, are activated or deactivated respectively a series of reed switches that generate an output proportional to the height of the level.
-Technical data
· Process connection: Top screw. 2" G. SS AISI316 (1.4401)
· Electrical connection: Connector DIN43650
· Length: 150..2500 mm
· Float: Cylindrical ø52x52 mm. SS AISI316 (1.4401)
· Temperature: -20..+100 ºC
· Pressure: 30 kg/cm²
+ Documentation
· Data sheet
· Declaration of conformity CE
· 3D file [.ZIP]
· Safety, installation and maintenance instructions
+Ordering
· Determine the total length according to the characteristics of the tank and the liquid level you want to control.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+
CONFIGURATOR:
Process connection
1"G
Float
Ø29x50 PA B
The float must be smaller in diameter than the process connection.
Step between readings
Length (mm)
The final length is calculated based on different parameters and may be different from that requested.
Zone E (mm)
Separation between the process connection and the electrical connection.
Zone S (mm)
Distance without reading between the process connection and the highest position of the float.
Electrical connection
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· They are used to obtain a continuous reading of liquid level.
· When the float rises or falls due to the action of the liquid, are activated or deactivated respectively a series of reed switches that generate an output proportional to the height of the level.
-Technical data
· Process connection: Top screw. 2´´ G. PP
· Electrical connection: Connection housing. PBT
· Length: 150..2500 mm, tube SS AISI316 (1.4401)
· Float: Cylindrical ø29x50 mm. PA
· Temperature: -10..+80 ºC
· Pressure: 3 kg/cm²
+ Documentation
· 3D file [.ZIP]
· Safety, installation and maintenance instructions
+Ordering
· Determine the total length according to the characteristics of the tank and the liquid level you want to control.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+
CONFIGURATOR:
Process connection
1"G
Float
Ø29x50 PA B
The float must be smaller in diameter than the process connection.
Step between readings
Length (mm)
The final length is calculated based on different parameters and may be different from that requested.
Zone E (mm)
Separation between the process connection and the electrical connection.
Zone S (mm)
Distance without reading between the process connection and the highest position of the float.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· They are used to obtain a continuous reading of liquid level.
· When the float rises or falls due to the action of the liquid, are activated or deactivated respectively a series of reed switches that generate an output proportional to the height of the level.
-Technical data
· Process connection: Top screw. 2´´ G. PP
· Electrical connection: Connector DIN43650
· Length: 150..2500 mm, tube SS AISI316 (1.4401)
· Float: Cylindrical ø29x50 mm. PA
· Temperature: -10..+80 ºC
· Pressure: 3 kg/cm²
+ Documentation
· Data sheet
· Declaration of conformity CE
· 3D file [.ZIP]
· Safety, installation and maintenance instructions
+Ordering
· Determine the total length according to the characteristics of the tank and the liquid level you want to control.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+
CONFIGURATOR:
Process connection
Float
The float must be smaller in diameter than the process connection.
Step between readings
Length (mm)
The final length is calculated based on different parameters and may be different from that requested.
Zone E (mm)
Separation between the process connection and the electrical connection.
Zone S (mm)
Distance without reading between the process connection and the highest position of the float.
Electrical connection
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· They are used to obtain a continuous reading of liquid level.
· When the float rises or falls due to the action of the liquid, are activated or deactivated respectively a series of reed switches that generate an output proportional to the height of the level.
-Technical data
· Process connection: Top screw. 2" G. SS AISI316 (1.4401)
· Electrical connection: Connection housing. PBT
· Length: 150..2500 mm
· Float: Cylindrical ø52x52 mm. SS AISI316 (1.4401)
· Temperature: -20..+100 ºC
· Pressure: 30 kg/cm²
+ Documentation
· Data sheet
· Declaration of conformity CE
· 3D file [.ZIP]
· Safety, installation and maintenance instructions
+Ordering
· Determine the total length according to the characteristics of the tank and the liquid level you want to control.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+
CONFIGURATOR:
Process connection
1"G
Float
Ø29x50 PA B
The float must be smaller in diameter than the process connection.
Step between readings
Length (mm)
The final length is calculated based on different parameters and may be different from that requested.
Zone E (mm)
Separation between the process connection and the electrical connection.
Zone S (mm)
Distance without reading between the process connection and the highest position of the float.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· They are used to obtain a continuous reading of liquid level.
· When the float rises or falls due to the action of the liquid, are activated or deactivated respectively a series of reed switches that generate an output proportional to the height of the level.
-Technical data
· Process connection: Top screw. 2" G. PVC
· Electrical connection: Connector DIN43650
· Length: 150..2500 mm, tube SS AISI316 (1.4401)
· Float: Cylindrical ø29x50 mm. PA
· Temperature: -10..+60 ºC
· Pressure: 3 kg/cm²
+ Documentation
· Data sheet
· Declaration of conformity CE
· Safety, installation and maintenance instructions
+Ordering
· Determine the total length according to the characteristics of the tank and the liquid level you want to control.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+
CONFIGURATOR:
Process connection
1"G
Float
Ø29x50 PA B
The float must be smaller in diameter than the process connection.
Step between readings
Length (mm)
The final length is calculated based on different parameters and may be different from that requested.
Zone E (mm)
Separation between the process connection and the electrical connection.
Zone S (mm)
Distance without reading between the process connection and the highest position of the float.
Electrical connection
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· They are used to obtain a continuous reading of liquid level.
· When the float rises or falls due to the action of the liquid, are activated or deactivated respectively a series of reed switches that generate an output proportional to the height of the level.
-Technical data
· Process connection: Top screw. 2" G. PVC
· Electrical connection: Connection housing. PBT
· Length: 150..2500 mm, tube SS AISI316 (1.4401)
· Float: Cylindrical ø29x50 mm. PA
· Temperature: -10..+60 ºC
· Pressure: 3 kg/cm²
+ Documentation
· 3D file [.ZIP]
· Safety, installation and maintenance instructions
+Ordering
· Determine the total length according to the characteristics of the tank and the liquid level you want to control.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+
CONFIGURATOR:
Process connection
2"1/2G
Float
Ø52x52 B
The float must be smaller in diameter than the process connection.
Step between readings
Length (mm)
The final length is calculated based on different parameters and may be different from that requested.
Zone E (mm)
Separation between the process connection and the electrical connection.
Zone S (mm)
Distance without reading between the process connection and the highest position of the float.
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· They are used to obtain a continuous reading of liquid level.
· When the float rises or falls due to the action of the liquid, are activated or deactivated respectively a series of reed switches that generate an output proportional to the height of the level.
-Technical data
· Process connection: Flange Clamp. 2"1/2 G. SS AISI316 (1.4401)
· Connexion electrical: Connector DIN43650
· Length: 150..2500 mm
· Float: Cylindrical ø52x52 mm. SS AISI316 (1.4401)
· Temperature: -20..+100 ºC
· Pressure: 30 kg/cm²
+ Documentation
· Data sheet
· Declaration of conformity CE
· 3D file [.ZIP]
· Safety, installation and maintenance instructions
+Ordering
· Determine the total length according to the characteristics of the tank and the liquid level you want to control.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.
+Table of chemical resistance
Substance
Other names
+
CONFIGURATOR:
Process connection
2"1/2G
Float
Ø52x52 B
The float must be smaller in diameter than the process connection.
Step between readings
Length (mm)
The final length is calculated based on different parameters and may be different from that requested.
Zone E (mm)
Separation between the process connection and the electrical connection.
Zone S (mm)
Distance without reading between the process connection and the highest position of the float.
Electrical connection
It remains to be decided
Select a product to display its configuration data
Reference
aaaa
CodeWeight (kg)Dimensions (mm)
Delivery time
The delivery time is expressed in working days. It... [Know more]
· They are used to obtain a continuous reading of liquid level.
· When the float rises or falls due to the action of the liquid, are activated or deactivated respectively a series of reed switches that generate an output proportional to the height of the level.
-Technical data
· Process connection: Flange Clamp. 2"1/2 G. SS AISI316 (1.4401)
· Electrical connection: Connection housing. PBT
· Length: 150..2500 mm
· Float: Cylindrical ø52x52 mm. SS AISI316 (1.4401)
· Temperature: -20..+100 ºC
· Pressure: 30 kg/cm²
+ Documentation
· Data sheet
· Declaration of conformity CE
· 3D file [.ZIP]
· Safety, installation and maintenance instructions
+Ordering
· Determine the total length according to the characteristics of the tank and the liquid level you want to control.
· Check that the conditions of pressure and temperature of the installation match with the ones allowed by the model chosen.
· If you have questions about the chemical behavior of materials in contact with the liquid you want to operate, refer to Table of chemical resistance.
· For all options, see the table "Reference" in the technical documentation of the selected model.