Magnetic switches of variable length

Standard design, with racord, SS

· For the detection of one or more level points.
· Used in maneuvers for filling, emptying, overfill alarm, etc.
· Custom fabrication to suit the installation conditions.

· Made in SS AISI316 (1.4401)
· Process connection: Nipple. 3/8"-1/2" G (depending the model).
· Float: Spherical ø52 mm
· Contacts: (NO) 120W/VA-3A/250VAC/DC
· Contacts: (NC - NO/NC) 60W/VA-1A/230VAC/DC
· Density: 0,7 g/cm³
· Pressure: 30 kg/cm²
CONFIGURATOR:
Version
Internal mode protection
Process connection
Float
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
Cable (m)

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· Length: 90..3500 mm
· Electrical connection: PVC/Silicone cable
· Temperature: -40..+125ºC
· Protection: IP65
CONFIGURATOR:
Version
Internal mode protection
Process connection
Float
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.
Cable (m)

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· For installation in the tank side
· Length: 90..1000 mm
· Electrical connection: PVC/Silicone cable
· Temperature: -40..+125ºC
· Protection: IP65
CONFIGURATOR:
Version
Internal mode protection
Process connection
With 3/8"G thread the connector is M8.
With 1/2"G thread the connector is M12.
Float
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· Length: 90..3500 mm
· Electrical connection: Miniature connector M8/M12
· Temperature: -40..+90ºC
· Protection: IP67
CONFIGURATOR:
Version
Internal mode protection
Process connection
With 3/8"G thread the connector is M8.
With 1/2"G thread the connector is M12.
Float
The float must be smaller in diameter than the process connection.
Length (mm)
Number of contacts
The number of contacts depends on the operation to be performed.
Number of floats
The number of floats must be equal to or less than the number of contacts.

It remains to be decided
Select a product to display its configuration data
Quantity
Add to cart (+34) 934 560 995


· For installation on the side of the tank
· Length: 90..1000 mm
· Connecting power: Miniature connector M8/M12
· Temperature: -40..+90ºC
· Protection: IP67